Fix it

No hot water? Water heater troubleshooting

Find why there's no hot water, and when it's a plumber's job.

If you smell gas (rotten eggs) near a gas water heater, don't touch switches or use a phone inside: get everyone out and call the gas company from outside. On a gas tank, look through the window at the bottom: no pilot flame means relight it by the label on the tank (knob to OFF, wait at least 5 minutes, then PILOT and the igniter), and a pilot that won't stay lit usually means a worn thermocouple or a clogged air intake. On an electric tank, check its double breaker (30 A on most 40–50 gal tanks), then press the red reset button behind the upper panel with the breaker off; if it trips again or stays cold, an element (usually the lower one) or a thermostat has failed. A tankless heater with no code needs a hot tap open all the way (Rinnai: about 0.4–0.6 GPM to start), gas, power and a clean inlet filter.

Updated · From A. O. Smith, Rheem, Bradford White, Resideo, Rinnai and Navien manuals; CPSC and PNNL on the stops · Not yet reviewed by a licensed plumber

What's going on?

Every question and every fix

Is any of this happening?

Stop: Gas smell: get out, then call

A rotten-egg smell near a gas water heater can be a gas leak. A spark from a switch, a phone or the heater itself can set it off.

  • Don't touch light switches, don't use a phone inside, and don't try to light anything.
  • Get everyone out, leaving the door open behind you.
  • From outside, call the gas company's emergency line or 911.
  • Stay out until they say it's safe.

Call the gas company from outside.

Stop: Carbon monoxide: get to fresh air now

A gas water heater that doesn't vent properly fills the room with carbon monoxide. You can't see or smell it.

  • Get everyone, and pets, outside right away.
  • Call 911 or the fire department from outside.
  • Turn the heater's gas knob to OFF only if you're still inside next to it; don't go back in for it.
  • Have the venting checked before it runs again.

Call 911 from outside.

Stop: It isn't venting: turn it off and call a plumber

Soot, scorch marks, melted plastic on top, or a flame rolling out of the burner door mean the exhaust is spilling back into the room (backdrafting, PNNL): carbon monoxide.

  • Turn the gas knob to OFF.
  • Open a window and keep people out of that room.
  • Put a CO alarm near it if you don't have one.
  • Call a plumber or HVAC tech to check the vent and the burner. Don't relight it until they have.

Call a plumber.

Stop: The tank itself is leaking: it needs replacing

Water from the tank body, or the seam at its base, means the lining has rusted through. It can't be patched (A. O. Smith), and it can let go all at once.

  • Close the cold-water valve on the pipe into the top of the heater.
  • Gas: turn the knob to OFF. Electric: switch its breaker off.
  • If the floor can't take more water: a hose from the drain valve to a floor drain or outside, open a hot tap upstairs, and open the drain valve.
  • Price the replacement, and call a plumber.

Call a plumber.

Stop: The relief valve is releasing: keep away

Hot water or steam blowing from the relief valve means the tank got too hot or the pressure too high. It's doing its job, and the water can scald (the National Board).

  • Don't stand in front of the pipe, and don't try to close or cap it.
  • Turn off the heat: gas knob to OFF, or the breaker off.
  • Close the cold-water valve into the heater only if you can reach it without getting near the spray.
  • Call a plumber today: the thermostat or the gas valve has failed.

Call a plumber.

Stop: Water near the controls: power off first

Water on an electric heater's panels or wiring, or on a gas valve's control, can shock or damage the control.

  • Electric: switch its breaker off before you touch anything wet. Gas: turn the knob to OFF.
  • Find where the water comes from (the next questions help), and let the controls dry for a day.
  • A gas control or a thermostat that got soaked is replaced by a plumber before it runs again.

Power off, then find the leak.

What kind of water heater?

A gas tank has a burner door and a flue pipe on top; an electric one two small panels on the side and a cable; a heat pump a fan unit on top; tankless is a box on the wall.

What's it doing?

Is the pilot lit?

Look through the small window near the bottom of the tank.

Try this first

  1. Check the gas knob isn't on OFF or VACATION.
  2. Check other gas appliances work: the gas may be off at the meter.

Relight the pilot, by the label

Why: A standing pilot goes out from a draft, a gust down the vent, or a dirty pilot. Relighting it by the label's own steps is a homeowner job.

  1. Read the lighting instructions on the label on the tank, and follow them where they differ from these.
  2. Turn the gas knob to OFF and wait at least 5 minutes for any gas to clear. Smell gas: stop, leave and call the gas company from outside.
  3. Turn the knob to PILOT, push it down (or hold the pilot button), and press the igniter button until you see the flame through the window.
  4. Keep holding for about a minute after it lights, then let go slowly. It should stay lit.
  5. Turn the knob to ON and set the temperature to about 120 °F (the "Hot" or "A" mark on many valves). The burner should light with a soft whoosh.
  6. It won't light after 2 or 3 tries, or goes out again: stop trying. That's the next answer, "won't stay lit".

Sealed tanks (FVIR, every 30–50 gal gas tank since 2003) are lit with the igniter through the sealed door: never open the burner chamber.

It won't stay lit: the thermocouple or a dirty air intake

Why: The pilot heats a thermocouple (or a thermopile) that holds the gas valve open. A worn one, a dirty pilot or a blocked air intake lets the pilot go out (A. O. Smith).

  1. Turn the knob to OFF. At the bottom of a sealed tank, vacuum the air intake screen (the flame arrestor) of lint and dust gently.
  2. Try lighting once more, by the label.
  3. It still goes out: the thermocouple, the thermopile or the pilot assembly needs a plumber. On sealed tanks the burner chamber isn't a homeowner's to open (Bradford White).
  4. Paint, gasoline or solvents in that room: move them out. Their fumes trip the flammable-vapor sensor, and some brands then need a new heater (A. O. Smith).

The pilot is lit, but it doesn't heat

Why: The thermostat is set low, or the gas control valve (the thermostat and gas valve in one) has failed.

  1. Turn the temperature dial up a notch and wait 10 minutes: the burner should light with a whoosh.
  2. Nothing: the gas control valve has failed. A plumber replaces it, never a homeowner (it's on the gas line).

A power-vent or electronic-ignition heater

Why: These light with an igniter and a fan, run on 120 V, and show a code when something stops them.

  1. Check it's plugged in, and that the outlet has power (and its breaker or GFCI isn't tripped).
  2. Read the blink count or the code on its display, against the chart on the label or in the manual.
  3. Turn it off for 5 minutes, then on, once. It locks out again: call a plumber (the vent, the fan and the gas valve are theirs).

Which sounds like it?

It may be too small for your busiest hour

Why: A tank's first-hour rating (on its label) is how much hot water it gives in an hour. Showers back to back can outrun it, more so in winter, when the water coming in is colder.

  1. Space showers out, or run the dishwasher and the laundry at another time.
  2. Check the size you need against your busiest hour.

Sediment on the bottom: flush it

Why: Minerals settle at the bottom of the tank. Water trapped under them boils: the rumbling and popping. It wastes energy and shortens the tank's life (A. O. Smith).

  1. Flush it: power or gas off, drain it through a hose, and run cold through until it's clear. The flush page has the steps for your heater.
  2. Over 8 years old and never flushed: have a plumber do it. Hard sediment can keep the drain valve from closing again (Rheem).

Parts: wh hose.

A broken dip tube

Why: The dip tube carries cold water to the bottom of the tank. When it breaks, cold water mixes in at the top: lukewarm water, and bits of white plastic in the faucet screens.

  1. Clean the faucet aerators and look for white plastic bits.
  2. A plumber replaces the dip tube (about an hour); on an old tank, price the replacement instead.

Two flashes: the pilot is weak

Why: On a Resideo (Honeywell) gas valve, 2 flashes means the thermopile isn't making enough voltage: usually a weak or dirty pilot flame.

  1. Look at the pilot through the window: it should be a strong blue flame wrapping the thermopile.
  2. Vacuum the air intake screen at the bottom, with the knob at OFF.
  3. Still 2 flashes: a plumber cleans the pilot or replaces the thermopile.

The gas valve reports a fault

Why: On a Resideo valve: 4 flashes = the temperature limit tripped, 5 = a sensor failed, 7 = the valve's electronics, 8 = the knob is off but the flame hasn't died down (Resideo).

  1. Turn the knob to OFF and wait 10 minutes. 8 flashes: wait until the light stops before relighting.
  2. Relight once, by the label.
  3. The code comes back: call a plumber. The valve isn't a homeowner part.

Which is it?

The anode rod is used up

Why: The anode rod rusts away so the tank doesn't. Once it's gone, the tank starts rusting: brown hot water, and soon a leak.

  1. Turn off the power or gas and the cold-water valve, open a hot tap, and drain a few gallons.
  2. Unscrew the anode (a hex head on top, under a plastic cap; a 1-1/16 in socket).
  3. Replace it if more than 6 in of the steel core wire shows (GE). Low ceiling: a flexible rod.
  4. Rusty water and an old tank: the tank may be rusting too. Price the replacement.

Some heaters' anode is in the hot outlet fitting (Bradford White): a combination rod with a nipple.

Parts: wh anode mg, wh anode socket.

Both taps: it isn't the heater

Why: Rusty water from the cold tap too comes from the pipes or the water supply, not the water heater.

  1. Run the cold tap for a few minutes. Just after work on the street's water main it clears on its own.
  2. It doesn't: call the water utility (or test the well), then a plumber for old iron pipes.

A rotten-egg smell from the hot water

Why: Bacteria in the water react with a magnesium anode and make hydrogen sulfide: the smell (A. O. Smith).

  1. Replace the anode with an aluminum-zinc one (the steps are the same as any anode).
  2. Flush the tank and disinfect it as your heater's manual says (a chlorine flush).
  3. Never just pull the anode out: the tank then rusts through, and it voids the warranty (A. O. Smith).
  4. The cold water smells too: it's the water supply (a well), not the heater.

Parts: wh anode alzn, wh anode socket.

Where does the water come from?

Dry everything with a towel, then watch where it reappears.

The drain valve drips

Why: The drain valve at the bottom wears, or grit keeps it from closing.

  1. Make sure it's closed all the way, and put a hose cap on its threads: that stops most drips.
  2. Still dripping: replace it with a brass ball valve. The tank has to be drained first (power or gas off). On an old tank, a plumber.

Parts: wh drain valve, wh hose.

A fitting on top leaks

Why: The connectors to the hot and cold pipes, or the fittings into the tank, can drip as they age.

  1. Dry everything and watch: water running down the outside from the top isn't a tank leak.
  2. Tighten a connector nut a quarter turn with two wrenches (one holds the fitting).
  3. Corroded or still dripping: a plumber replaces the connectors (cold valve closed first).

Parts: wh connector 18.

How does the relief valve leak?

The valve on the side or top, with a pipe running down toward the floor.

Thermal expansion: an expansion tank

Why: Heated water expands. With a check valve or a pressure regulator on the main, it has nowhere to go, and the relief valve lets a little out (GE). The plumbing code wants an expansion tank then (IRC P2903.4.2).

  1. Never plug or cap the relief valve or its pipe (GE).
  2. A plumber fits an expansion tank on the cold pipe (it's cut into the plumbing).
  3. House pressure over 80 psi makes it worse: a gauge on an outside faucet tells you (A. O. Smith: 50–60 psi is right).

Parts: wh exp tank (what the plumber fits).

The relief valve is worn

Why: A relief valve that trickles all the time, even with the water cool, doesn't seal any more.

  1. Lift its lever once and let it snap shut: grit can hold it open.
  2. Still trickling: a plumber replaces it. Never plug it.

Heat pump: water from the condensate hose

Why: A heat pump water heater pulls water out of the air, like a dehumidifier, and drains it through a hose or a small pump.

  1. Find the condensate hose (it leaves the top or the side): it must run downhill to a drain, with no kinks or sags full of water.
  2. Clear a blocked end, or empty and clean the condensate pump if it has one.
  3. Water from the tank itself: that's a leak, not condensate.

Turn it down to 120 °F

Why: At 140 °F, hot water burns skin in about 6 seconds; at 120 °F it takes about 5 minutes (CPSC). 120 °F is the setting the CPSC recommends.

  1. Gas or a display: turn the dial to the "Hot" or 120 °F mark (often an "A" or a small triangle).
  2. Wait a few hours, and check at a faucet with a thermometer.
  3. Electric: the dials are behind the panels, next to live wires. Follow the gated answer under "electric", or a plumber sets them.

What's it doing?

What did the breaker do?

Try this first

  1. Find its double breaker in the panel (30 A on most 40–50 gal tanks).
  2. Push it all the way OFF, then ON.

Stop: The breaker trips again at once: leave it off

A breaker that trips right away has a short behind it: usually an element that cracked and shorted to the tank, or burned wiring.

  • Leave the breaker off.
  • Don't press the heater's reset button again.
  • Call a plumber or an electrician.

Call a plumber.

Did the reset button bring it back?

Try this first

  1. Switch the breaker off.
  2. Unscrew the upper access panel and fold the insulation aside. Touch nothing but the red button.
  3. Press the red reset button firmly. A click means it had tripped.
  4. Insulation and panel back, breaker on, and wait an hour.

It had overheated once

Why: The red button is the high-limit (ECO) switch: it cuts the power when the water gets too hot. One trip can be a fluke; repeated trips mean a shorted element or a stuck thermostat (A. O. Smith).

  1. Keep the panel covers on and watch it for a week.
  2. It trips again: test the elements and thermostats (start again, "it trips again"), or call a plumber.

Test the elements, and replace the bad one

Why: A burned-out element (most often the lower one) or a failed thermostat. An element is tested with a multimeter, the power off (A. O. Smith).

  1. Take a photo of the wiring, then loosen one wire from each element's screws.
  2. Multimeter on ohms: across an element's two screws, a good one reads 5–25 Ω (about 13 for 4,500 W, 10.5 for 5,500 W). Open, or 0: bad. From either screw to the tank, a good one reads nothing at all.
  3. Both elements good: a thermostat is the likely fault, usually the lower one (A. O. Smith). Buy the same type, and move the wires one at a time.
  4. A bad element: close the cold-water valve, open a hot tap, and drain the tank below that element with a hose to a drain.
  5. Unscrew it with a 1-1/2 in element socket. The new one, the same voltage and wattage as the label (most 240 V, 4,500 W), goes in with its new gasket.
  6. Close the drain, open the cold valve, and let the hot tap run until water flows steadily: the tank must be full.
  7. Only then: wires on, covers on, breaker on. Power to an empty tank burns a new element out in seconds (Rheem).

Electric water heater work under the covers is 240 V. Unsure at any step: stop, and a plumber does it.

Parts: wh multimeter, wh element 4500 (or 5,500 W: match the label), wh element socket, wh hose, wh tstat lower (only if both elements test good).

Which sounds like it?

Turn both thermostats down to 120 °F

Why: At 140 °F hot water burns skin in about 6 seconds; at 120 °F it takes about 5 minutes (CPSC). Electric tanks have two thermostats: set both the same.

  1. Unscrew both access panels and fold the insulation aside. Don't touch the wires or the screws.
  2. Turn each dial to 120 °F with a flat screwdriver.
  3. Insulation back, covers on, breaker on. Check at a faucet in a few hours.

What's it doing?

Heat pump: check the mode, the filter and the room

Why: A heat pump heats slowly by design, and needs air between about 40 and 90 °F around it (ENERGY STAR). A clogged filter or the wrong mode makes it fall behind.

  1. Read the display: the mode, and any error code against the manual.
  2. For a busy morning, switch to Hybrid or High Demand (it uses the elements too); Heat Pump or Efficiency mode is the slowest.
  3. Clean the air filter on top (most rinse in the sink).
  4. The room is colder than about 40 °F: it runs on its elements, slowly, or not at all.
  5. Check its breaker. Still cold with a code: call the installer or a plumber.

What's it doing?

Which code?

On the unit's display or the remote. Rinnai shows numbers; Navien shows E codes.

Scale inside: descale it

Why: Hard water leaves scale in the heat exchanger. Rinnai shows LC; Navien E016 / E030 (overheat); the flow gets weak and the water lukewarm.

  1. Descale it with a pump, hoses and 4 gal of white vinegar through the isolation valves: the flush page has the steps.
  2. No isolation valves on the pipes: a plumber fits them once; after that it's a 1-hour DIY job.
  3. Hard water: a softener or a scale filter in front of it (Navien requires one over 12 gpg).

Parts: wh tl kit, wh tl descaler.

No ignition or the flame went out

Why: Rinnai 11 / 12 and Navien E003 / E012: the burner didn't light or lost its flame. Usually gas: a closed valve, an empty propane tank, or low gas pressure (Navien).

  1. Check the gas valve on the pipe into the heater is open (the handle along the pipe), and other gas appliances work.
  2. Navien E012: clean the air filter (Navien's manual).
  3. Turn it off and on once.
  4. The code returns: call a plumber. The gas and the burner are theirs.

Stop: Code 10: the air or exhaust is blocked

Rinnai's code 10 means the unit can't breathe or vent. Running it that way can push exhaust into the house.

  • Turn it off at its power switch or plug.
  • From outside, look at the vent caps on the wall or roof: snow, leaves, a nest. Clear only what you can reach safely from the ground; never take the vent apart.
  • Turn it back on once. Code 10 again: call a plumber or the installer.

Call a plumber.

A part has failed: a service call

Why: Rinnai 14 (the thermal fuse) and 16 (over-temperature), Navien E407 (a sensor) and E515 (the board): parts a homeowner doesn't replace (Rinnai, Navien).

  1. Turn it off and on once. Rinnai 16: a scaled heat exchanger can cause it, so a descale may clear it.
  2. The code returns: call the installer or a plumber, with the code and the model.

Look it up in the manual

Why: Codes differ by model. The manual (on the maker's site by model number) gives the meaning and the safe first check.

  1. Find the model number on the side label, and the code in its manual.
  2. Do only the checks the manual gives a homeowner, then turn it off and on once.
  3. The code returns: call a plumber.

Tankless, no code: flow, gas and the filter

Why: A tankless heater only lights above a minimum flow (Rinnai: about 0.4–0.6 GPM to start) and with gas and power.

  1. Open a hot tap all the way: a trickle may not light it.
  2. Check it has power (the display is on), and that other gas appliances work.
  3. Clean the cold-water inlet filter (close the cold valve first; Rinnai, Navien): a clogged one cuts the flow.
  4. Clean the aerators on the faucets.
  5. Still nothing: call the installer or a plumber.

Hot, then a burst of cold: that's normal

Why: The "cold-water sandwich": when you turn the hot back on, the water left in the pipe is hot, then comes cold while the heater relights. It can be reduced but not removed (Rinnai).

  1. Leave the hot tap on: it settles in a few seconds.
  2. A small buffer tank or a recirculation pump reduces it: ask the installer.

The light on a gas valve

A Resideo (Honeywell) valve, on many Bradford White, A. O. Smith and State tanks. Count the flashes between pauses. Another valve: the chart on its label.

FlashesMeansYou
1 every 3 sNormal, readynothing
Fast strobeHeatingnothing
2Low thermopile voltagecheck the pilot flame; again: a plumber
4The temperature limit trippeda plumber
5A temperature sensor faileda plumber
7The valve's electronics faileda plumber
8Knob off, the flame not out yetwait for the light to stop, then relight

Tankless codes

The common ones. Your model's manual has the full list.

CodeMeansFirst check
Rinnai LCScale building up (it still runs)descale it
Rinnai 10Air or exhaust blockedthe vent caps outside; then a plumber
Rinnai 11, 12No ignition, flame lostthe gas valve is open, other gas appliances work
Rinnai 14, 16Thermal fuse, overheatinga plumber (16: a descale may clear it)
Navien E003Ignition failurethe gas valve is open
Navien E012Flame lostclean the air filter
Navien E016, E030Overheatclean the inlet filter, descale
Navien E407, E515A sensor, the boardcall support or a plumber

Where the answers come from

  1. Gas and electric tanks: A. O. Smith's troubleshooting charts and No Hot Water guide, Rheem, GE Appliances, Bradford White's service manual, Resideo's gas valve guide.
  2. Tankless: the Rinnai FAQ and manuals, the Navien NPE-2 manual.
  3. The stops: PNNL (backdrafting), the National Board (relief valves), CPSC (scald times), state gas safety (a gas smell).

You may

Relight
a standing pilot, by the label
Reset
an electric heater's red button, once, power off
Replace
an element or thermostat, power off and tested; an anode rod
Flush
and turn the temperature down to 120 °F
Never
the gas line, the gas valve, the burner, the venting, or plug the relief valve

Not yet reviewed by a licensed plumber. Your heater's label and manual win where they differ.

Questions people ask

How do I relight a water heater pilot light?

Follow the steps on the label on the tank. Usually: turn the knob to OFF and wait 5 minutes, turn it to PILOT, hold it down while you press the igniter until the pilot lights, keep holding about a minute, then let go and turn it to ON. If you smell gas, stop and call the gas company from outside.

Why does my water heater pilot keep going out?

Usually a worn thermocouple (or thermopile), a dirty pilot, or a clogged air intake at the bottom of a sealed tank (A. O. Smith). Vacuum the intake screen and try once more; if it still goes out, a plumber replaces the part. On sealed tanks the burner chamber isn't a homeowner's to open.

Why is there no hot water but the pilot is lit?

The temperature is set too low, or the gas control valve has failed. Turn the dial up and wait 10 minutes; if the burner still doesn't light, a plumber replaces the gas valve.

Why does my electric water heater have no hot water?

Check its breaker first, then the red reset button behind the upper panel (power off). If it trips again or stays cold, an element (usually the lower one) or a thermostat has failed: test them with a multimeter, power off (A. O. Smith).

Where is the reset button on a water heater?

On an electric tank, behind the upper access panel, on the upper thermostat: a red button. Switch the breaker off before you open the panel. Gas tanks have no reset button you press; some sealed ones have a thermal switch that a plumber deals with.

More apps