Flush a tank water heater yearly, or every 6 months with hard water, over 7 gpg (Rheem, A. O. Smith); it takes 1–2 hours, most of it waiting for the tank to cool, drain and refill. Turn the gas to OFF, or on an electric heater switch the breaker off before any water drains, then drain it through a hose and open the cold valve in bursts until the water runs clear. A tank 8 years or older that has never been flushed is a plumber's job (Rheem): hard sediment can keep the drain valve from closing or start a leak. A tankless heater is descaled yearly by pumping 4 gal of white vinegar through it for 45 (Navien) to 60 minutes (Rinnai).

Updated · Steps from A. O. Smith, Rheem, GE, Rinnai and Navien; hardness classes from the USGS · Not yet reviewed by a licensed plumber

What you need

How often should you flush a water heater?

By your water's hardness (the USGS classes; your water utility's report gives it in gpg or mg/L, and gpg = mg/L ÷ 17.1). Not sure: once a year.

How often to flush a water heater, by water hardness
WaterHardnessTank (gas, electric, heat pump)Tankless
Softunder 3.5 gpgYearlyOnly when it shows a scale code
Moderate3.5–7 gpgYearlyYearly
Hard7–10.5 gpg, white crustEvery 6 monthsYearly; a softener or a scale filter is strongly recommended over 9 gpg
Very hardover 10.5 gpgEvery 6 monthsYearly; a softener or a scale filter: Navien requires one over 12 gpg

A plumber charges about $100–250 to flush a tank and $150–350 to descale a tankless heater (Angi, HomeGuide).

How do you flush a gas water heater?

  1. Turn the gas off. Turn the gas knob to OFF (A. O. Smith) and let the water cool for a few hours: it comes out scalding.
  2. Close the cold valve. Close the valve on the cold pipe into the top of the tank.
  3. Hose to a drain. Screw a garden hose onto the drain valve at the bottom and run it to a floor drain or outside, lower than the valve.
  4. Let air in. Open a hot tap in the house (or lift the relief valve's lever) so the tank can drain.
  5. Drain it. Open the drain valve. Sediment may clog it: close and reopen it, or use a flush tool.
  6. Stir it up. With the drain still open, open the cold valve for a few seconds at a time: the rush stirs the sediment out. Repeat until the water runs clear (GE).
  7. Refill. Close the drain valve, open the cold valve, and leave the hot tap open until water flows steadily: then the tank is full (GE).
  8. Gas back on. Relight by the label (or turn the knob back to ON) and set about 120 °F. Run hot taps for 3 minutes to clear the air (A. O. Smith).

An electric or heat pump tank is the same with one change: switch the breaker off before any water comes out, and only switch it back on once the tank is full and a hot tap runs steadily, or the element burns out (GE).

How do you descale a tankless water heater?

  1. Power and gas off. Turn the unit off (its switch or plug, or its breaker) and close the gas valve on the pipe into it (Rinnai).
  2. Close the isolation valves. Close the hot and cold isolation valves under the unit, and take the caps off the two purge ports.
  3. Hoses and pump. Pump in a bucket with 4 gal of undiluted white vinegar (Rinnai) or the maker's descaler: one hose from the pump to the cold purge port, one from the hot purge port back into the bucket.
  4. Circulate. Open both purge ports and run the pump: 45 (Navien) to 60 minutes.
  5. Rinse. Pump off, the hot-side hose into a drain, close the cold purge port, open the cold isolation valve, and let clean water run 5 minutes (Navien).
  6. Clean the inlet filter. Close the cold valve again, unscrew the cold inlet filter, rinse it and screw it back (Rinnai, Navien).
  7. Back in service. Purge ports closed and capped, both isolation valves open, gas on, power on. Open a hot tap slowly to clear the air (Rinnai).

How we work it out

  1. How often: a tank once a year, every 6 months with hard water (Rheem; A. O. Smith: at least yearly; GE: yearly).
  2. When not to: the drain valve won't open or leaks, heavy rust on the fittings, or 8–12+ years old and never flushed (Rheem). Then it's a plumber's job, and maybe time to price a new one.
  3. Tankless: by hardness (Navien): under 4 gpg only when a scale code shows; 4–9 gpg yearly; over 9 a softener or scale filter is strongly recommended, over 12 required. Circulate 45 minutes (Navien) to an hour (Rinnai).

The numbers we use

Hardness
soft under 3.5 gpg, moderate 3.5–7, hard 7–10.5, very hard over 10.5 (USGS; gpg = mg/L ÷ 17.1)
Vinegar
4 gal, undiluted (Rinnai)
Anode
replace when more than 6 in of core wire shows (GE)
A pro flush
$100–250; a tankless descale $150–350 (Angi, HomeGuide)

Sources: A. O. Smith, Rheem, GE Appliances, Rinnai, Navien NPE-2 manual. Your heater's manual wins where it differs. Not yet reviewed by a licensed plumber.

Questions people ask

How often should I flush my water heater?

Once a year, or every 6 months with hard water (Rheem; A. O. Smith says at least yearly). A tankless heater is descaled yearly with moderate or hard water; with soft water, when it shows a scale code (Navien, Rinnai).

How do I flush a water heater?

Turn the gas to OFF or the breaker off (before any water drains, on an electric one), close the cold valve, run a hose from the drain valve to a drain, open a hot tap and drain it. Open the cold valve in bursts until the water runs clear, then refill until a hot tap runs steady before the gas or power goes back on (GE, A. O. Smith).

Should I flush an old water heater?

Not yourself if it's 8 years or older and has never been flushed, or the drain valve won't open or leaks: hard sediment can keep the valve from closing or start a leak (Rheem). Have a plumber do it, and price the replacement first.

How do I descale a tankless water heater?

Power and gas off, close the isolation valves, and pump 4 gal of undiluted white vinegar through the purge ports for 45 minutes to an hour (Navien, Rinnai). Rinse 5 minutes with clean water, clean the inlet filter, and put it back in service.

What happens if you never flush a water heater?

Sediment builds up on the bottom: it rumbles and pops, heats slower, wastes energy, and wears the tank out sooner (A. O. Smith).