Fix it

AC not cooling?

Find why your AC isn't cooling, and when it's a technician's job.

Most of the time an AC that isn't cooling has the wrong thermostat setting, a tripped breaker, a clogged filter, a dirty outdoor coil or a clogged condensate drain: set it to Cool at least 3 °F below the room with the fan on Auto, change a filter over a month old, and go look at the outdoor unit. A silent outdoor unit has no power or no signal: push its double breaker fully off, then on, once, check the disconnect box beside it, and wait 5 minutes. An outdoor unit that runs, with a clean filter and clean fins, but warm air inside usually means a refrigerant leak, which only an EPA-certified technician can fix. Stop and call a technician if the breaker trips again right after a reset, the outdoor unit hums but its fan doesn't spin (often a capacitor, which can shock you even with the power off), or you smell burning.

Updated · From Carrier, Trane, Goodman and Daikin guides, ENERGY STAR and EPA Section 608 · Not yet reviewed by a licensed HVAC tech

What's going on?

Every question and every fix

Before anything else: do you notice any of these?

Stop: Turn it off: a burning smell or smoke

A burning or hot-electrical smell from the vents or the outdoor unit can be a motor or wiring overheating.

  • Set the thermostat to Off.
  • Switch off the AC's breakers (the outdoor unit's double breaker and the furnace or air handler) if you can reach the panel safely.
  • Smoke you can see, or flames: get everyone out and call 911 from outside.
  • Don't turn it back on until a technician has checked it.

Call an HVAC technician (911 for smoke or fire).

Stop: The breaker trips again: leave it off

A breaker that trips again right after you reset it is protecting the wiring from a fault, often a failing compressor, fan motor or capacitor (Carrier: if it trips again, call a professional).

  • Leave the breaker off. Don't hold it on, and don't keep resetting it.
  • Set the thermostat to Off.
  • Note which breaker it is and what the unit did before it tripped.

Call an HVAC technician.

Stop: Humming, but the fan doesn't spin: a technician's job

The fan motor or the compressor is trying to start and can't, most often because a capacitor failed. A capacitor holds a charge that can shock you even with the power off (Daikin), and Carrier says not to troubleshoot capacitors, motors or the compressor yourself.

  • Set the thermostat to Off, so the compressor stops trying to start and overheating.
  • Switch off the disconnect by the outdoor unit, or its breaker.
  • Don't open the unit, and don't push the fan blades with a stick to start it.
  • Book a technician: a capacitor is usually a short visit.

Call an HVAC technician.

Where is the water coming from?

Do this now

  1. Set the thermostat to Off.
  2. Towels down. If water reaches the furnace's wiring or controls, switch off its breaker, standing on a dry floor.

Clear the condensate drain

Why: An AC pulls gallons of water out of the air each day. It drips into a pan and runs out a small pipe. Algae and dust clog it, the pan fills, and a float switch turns the AC off before it floods (Trane).

  1. Set the thermostat to Off, and switch off the furnace or air handler (its service switch or breaker).
  2. Find the drain: a white plastic pipe from the indoor coil, often with a capped T near it (the cleanout). Its other end comes out outside near the outdoor unit, or over a floor drain.
  3. Outside: hold a wet/dry vac hose tight over the pipe's end and run it for a minute or two to pull the clog out.
  4. Indoors: take the cap off the cleanout, pour in 1 cup of distilled white vinegar, wait 30 minutes, then pour in a cup or two of water (Carrier).
  5. Empty the pan with the vac or a sponge. The float switch drops and lets the AC run again.
  6. Power back on and Cool: within half an hour, water should drip from the outside end.
  7. A cup of vinegar at the start of summer and again midsummer keeps it clear.

Parts: ac shop vac (if you don't have one).

How is the pump connected?

Look at what comes out of the pump besides the tubing.

Clean or swap the condensate pump, like for like

Why: A small pump lifts the water when the drain can't run downhill (a basement furnace). Slime sticks its float, or the motor quits, and the tank overflows.

  1. Check the outlet with a lamp, and reset a GFCI if it's on one.
  2. Empty the tank into a bucket, or with a wet/dry vac.
  3. Clean the slime off the tank and the float with warm water: the float should move freely.
  4. Plug it in and pour in a cup of water: it should start pumping.
  5. Still silent, or it hums without pumping: replace it with one that takes the same tubing and lifts at least as high (both are on the label). Move the tubing over, plug in, and test with water.
  6. If the old pump had a safety switch (two thin wires), connect the new one the same way only if they ended in a plug-in connector.

Parts: ac condensate pump.

Stop: A wired-in pump is a technician's job

Some condensate pumps have a safety switch wired into the furnace or AC: it shuts the system off when the pump fills. Swapping it means working on the control wiring.

  • Set the thermostat to Off when the pump is full or leaking.
  • Empty the pump's tank with a wet/dry vac or a sponge to stop the overflow.
  • Book a technician, or an electrician who works on HVAC controls.

Call an HVAC technician.

Stop: Water on the controls: power off first

Water dripping onto the furnace's control board or wiring can short it, and touching wet live parts can shock you.

  • Only if you can reach the panel standing on a dry floor: switch off the furnace or air handler breaker (or its service switch).
  • Set the thermostat to Off.
  • Mop up, and leave the panel covers on.
  • A technician should check the board is dry and working before it runs, and find why the drain overflowed.

Call an HVAC technician.

Stop: Water through a ceiling: turn it off and call

An AC in the attic sits over a second pan that should have its own drain or float switch. Water coming through the ceiling means both failed, and a wet ceiling can sag and fall.

  • Set the thermostat to Off.
  • Put a bucket under the drip. A bulging ceiling: keep people away from under it.
  • Don't go into the attic over the wet drywall: step only on the joists, or wait for the technician.
  • Book a technician to clear the drain and check both pans.

Call an HVAC technician.

Stop: A rusted or cracked drain pan: a technician's job

Older metal pans rust through, and a cracked pan leaks no matter how clear the drain is. Replacing it means taking the coil out.

  • Set the thermostat to Off when water is leaking.
  • A wet/dry vac or towels keep the water down until the visit.
  • Book a technician.

Call an HVAC technician.

While it thaws: how are the filter and the vents?

Do this now

  1. At the thermostat: Cool off (or System Off), and the fan ON. The fan melts the ice faster (Carrier).
  2. Frost thaws in about 1–3 hours, thick ice in 4–8 hours or more. Don't chip it, and no hair dryer, heater or hot water.
  3. Put towels around the indoor unit: the melt water can overflow the pan.

A clogged filter froze the coil

Why: With too little air across it, the indoor coil drops below freezing and the moisture in the air turns to ice (Carrier).

  1. Let it thaw all the way: Cool off, fan on, 1–3 hours for frost, 4–8 hours or more for thick ice.
  2. Put in a new filter, arrow toward the furnace.
  3. Dry the pan and the area around the indoor unit.
  4. Back to Cool. If ice comes back, stop: a technician.

Closed or blocked vents froze the coil

Why: Too few open vents and returns means too little air over the coil, and it ices up (Carrier: keep the vents clear).

  1. Let it thaw all the way: Cool off, fan on.
  2. Open every supply vent, and move furniture and rugs off the returns.
  3. Back to Cool. If ice comes back, stop: a technician.

Stop: The ice comes back: a technician's job

Ice that returns with a clean filter and open vents means too little refrigerant (a leak) or too little air across the coil (the blower or a duct). Carrier: if it freezes again after you restart it, call a professional.

  • Thaw it again: Cool off, fan on.
  • Leave it off until the technician comes; running it iced up can damage the compressor.
  • Keep towels by the indoor unit for the melt water.

Call an HVAC technician.

What kind of air conditioning?

Central air and heat pumps have a big outdoor unit and vents in the rooms. A mini-split has a long indoor unit high on the wall.

What's it doing?

Did the thermostat bring it on?

Try this first

  1. Set it to Cool, at least 3 °F below the room temperature, with the fan on Auto.
  2. A blank screen: put new batteries in it (many take AA or AAA). No batteries: many thermostats get their power from the furnace, so check the breakers next.
  3. Wait 5 minutes: many systems wait a few minutes before they start again.

It was the thermostat

Why: A thermostat on Heat or Off, set above the room, on a schedule, or with flat batteries is the most common reason an AC doesn't come on (Carrier).

  1. Leave it on Cool with the fan on Auto.
  2. A schedule or "hold" can override what you set: check the program.
  3. Battery thermostats: put new batteries in each spring, before the low-battery warning.

What did the breakers show?

Central air has two: a double breaker for the outdoor unit and one for the furnace or air handler indoors.

Try this first

  1. In the panel, push any breaker that isn't lined up with the others fully OFF, then ON. Once.
  2. Check the furnace's service switch (it looks like a light switch, on or near the furnace) is on.
  3. Outside, check the disconnect box on the wall by the unit: the handle on, or the pull-out block pushed in the right way up.

It was the breaker

Why: An AC breaker can trip in a power surge or a heat wave. Once is nothing to worry about.

  1. Note which breaker it was.
  2. If it trips again, leave it off and call a technician (Carrier): repeat trips mean a failing part.
  3. Book a tune-up if it hasn't had one this year.

Is the furnace or air handler's lower panel shut tight?

A safety switch behind the lower panel (the blower door) turns the system off while it's open or loose (Goodman).

Try this first

  1. Push the lower panel firmly into its slots until it sits flat, and put its screws back if it has them.

It was the furnace door switch

Why: A switch behind the furnace or air handler's lower panel cuts the system when the panel is off or loose (Goodman), so nobody reaches into a running blower.

  1. Keep the panel seated in its slots, with its screws in if it has them.
  2. Never tape the switch or hold it shut: it's there to protect you.

Any water in the pan under the indoor coil?

A float switch shuts the AC off when the drain backs up, so it doesn't flood (Trane). Look under the coil: above the furnace, or in the attic, and along the drain pipe.

Stop: Nothing gets power: a technician's job

With the thermostat working, the breakers on, the furnace switch on and its panel shut, a system that does nothing has usually lost its control power: a transformer, a fuse on the control board, or a thermostat wire.

  • Set the thermostat to Off.
  • Don't open the control panel inside the furnace or air handler.
  • Tell the technician what you checked.

Call an HVAC technician.

Is the outdoor unit running?

Go outside and look and listen, with the thermostat on Cool. Don't open the unit or reach into it.

Try this first

  1. Check the thermostat: Cool, below the room temperature, and the fan on Auto. On ON, the fan keeps blowing between cooling runs, and that air isn't cold (Carrier).

When was the filter last changed?

A clogged filter starves the indoor coil of air (Carrier). ENERGY STAR says check it every month in summer.

Change the filter

Why: A clogged filter starves the indoor coil of air: weak, warm air, and in time, ice. ENERGY STAR says check it every month in summer.

  1. Set the thermostat to Off.
  2. Find the filter: in a slot by the furnace or air handler, or behind a return grille in a wall or ceiling. The size is printed on its edge.
  3. Put the new one in with the airflow arrow pointing toward the furnace, away from the return.
  4. Turn it back on. The air should be cold again within about 30 minutes.
  5. Check it monthly in summer and change it at least every 3 months (ENERGY STAR).

Ice on the pipes? Let it thaw first (Cool off, fan on), then change the filter.

What do the outdoor unit's fins look like?

The thin metal fins on its sides, from outside.

Clean the outdoor coil

Why: The outdoor unit gets rid of the heat from your house through its fins. Matted with dirt, cottonwood fluff or grass clippings, it can't, and the air indoors stops getting cold.

  1. Pull leaves, grass and twigs from around and on top of the unit by hand. Gloves: the fins are sharp.
  2. Brush the fins gently, up and down along them, with a soft brush. Straighten bent fins with a fin comb.
  3. Rinse the fins with a garden hose at normal pressure, from the top down. Never use a pressure washer: it flattens the fins (Carrier).
  4. A foaming coil cleaner made for outdoor units is optional: follow its label, then rinse.
  5. Let it dry for 30 minutes, then the breaker on, the disconnect on, and the thermostat back to Cool.
  6. Cleaning inside the unit, with the top and the fan taken off, is a technician's job (Carrier).

Parts: ac fin comb, ac coil cleaner (optional).

Give the outdoor unit room to breathe

Why: The outdoor unit pulls air in through its sides and blows it out the top. Shrubs, a fence, stored things or a cover trap the hot air around it.

  1. Keep 2 ft clear all around it (Carrier): trim shrubs and move stored things away.
  2. Nothing on top of it, and no cover while it's running.
  3. If the fins are dirty too, clean them (Start over: Air blows but isn't cold).

Stop: Probably a refrigerant leak: a technician's job

When the filter is clean, the outdoor coil is clean and the outdoor unit runs, warm air usually means low refrigerant, and refrigerant isn't used up: low means a leak. Since 2018 only EPA-certified technicians may buy refrigerant (EPA Section 608), and a top-off without fixing the leak just leaks out again.

  • Set the thermostat to Off: a compressor short of refrigerant can overheat.
  • Note any ice on the copper pipes, a hiss, or an oily spot on a pipe or joint.
  • Ask the technician to find and fix the leak, not just recharge it, and which refrigerant it uses. A system made before 2010 probably uses R-22: it hasn't been made since 2020 (EPA), so a top-off is expensive.
  • An older system: price the replacement before paying for a big repair.

Call an HVAC technician.

What did the breaker and the disconnect show?

Try this first

  1. In the panel: the double breaker for the AC (often labeled AC, condenser or heat pump). Push it fully OFF, then ON. Once.
  2. At the disconnect box by the unit: the handle on, or the pull-out block pushed in the right way up.
  3. Wait 5 minutes: the outdoor unit waits a few minutes before it starts.

Stop: Power reaches it, but the outdoor unit won't start

With the thermostat calling for cooling, the breakers on and the disconnect in, a silent or clicking outdoor unit usually means a failed contactor or capacitor, or a broken thermostat wire. All of them are inside the unit, live at 240 V.

  • Set the thermostat to Off.
  • Don't open the unit's panel.
  • Tell the technician what you checked (thermostat, breakers, disconnect, the furnace panel).

Call an HVAC technician.

How hot is it outside?

A heat wave can outrun a healthy AC

Why: Systems are sized for about the hottest 1% of hours where you live. In a heat wave a healthy AC can run all day and still fall behind (installers often say it holds about 20 °F below the outdoor temperature).

  1. Close the blinds on the sunny side, and skip the oven in the afternoon.
  2. Set it a few degrees lower early in the morning and let it hold, rather than turning it way down in the afternoon.
  3. Keep the fan on Auto, the filter clean and the outdoor unit clear.
  4. If it falls behind on normal summer days too, come back: Start over and choose "a normal summer day".

Did fixing the airflow help?

Try this first

  1. A filter more than a month old: change it.
  2. Open every supply vent, and move furniture and rugs off the return grilles.
  3. Check the thermostat isn't in the sun, or near a lamp or a vent.

It was the airflow

Why: A dirty filter, closed vents or blocked returns cut the air across the coil. Closing vents in empty rooms doesn't help: it can starve the coil of air and freeze it.

  1. Keep every supply vent open and the returns clear of furniture and rugs.
  2. Check the filter monthly in summer (ENERGY STAR).
  3. Keep the thermostat out of the sun and away from lamps and vents.

What do the outdoor unit's fins look like?

How much colder is the air at a vent?

Optional, with a cheap thermometer: after 15 minutes of cooling, measure in the return grille, then at the nearest vent. Many technicians expect it 14–20 °F colder at the vent, but it changes with the humidity (ACCA): a clue, not a test.

It may be too small, or the ducts leak

Why: A system that runs, cools the air 14–20 °F and still can't keep the house cool on a normal day may be undersized for the house, or losing its cold air through leaky ducts in a hot attic.

  1. Ask a technician to check the charge and the airflow first.
  2. Then ask for a Manual J load calculation for your house: it's the sizing the building code calls for.
  3. Ducts in the attic: ask for a duct leakage test. Sealing ducts is often cheaper than a bigger unit.

Have a technician check the charge and the airflow

Why: With the filter, the vents and the outdoor coil fine, what's left is the refrigerant charge, the blower and the ducts: a technician measures those.

  1. Note what you checked and when it cools worst.
  2. Ask for the system's pressures and the airflow to be measured, not guessed.
  3. Optional, before they come: a cheap thermometer in the return grille, then at the nearest vent after 15 minutes of cooling. Tell them both numbers.

Did the easy fixes stop it?

Try this first

  1. Change a dirty filter.
  2. Check nothing warm is near the thermostat: a vent, a lamp, a sunny window, the kitchen.
  3. Look for ice on the copper pipes.

Fixed: keep an eye on it

Why: A dirty filter or a thermostat that feels a vent, a lamp or the sun shuts the AC off early and turns it on again.

  1. Move anything warm away from the thermostat, or ask about moving the thermostat.
  2. Check the filter monthly in summer.
  3. Short runs again: a technician.

Stop: Short cycling: have it checked

An AC that keeps turning on and off every few minutes wears out early and doesn't dry the air. Common causes: a system too big for the house (DOE, NREL), low refrigerant, or a failing part.

  • Note how long each run lasts.
  • Ask the technician to check the charge and the controls.
  • If it's oversized, ask how it was sized: the code calls for a Manual J load calculation.

Call an HVAC technician.

What do you hear or smell?

Stop: Grinding or screeching: turn it off

A grinding, screeching or squealing sound is usually a fan or blower motor bearing failing, or something rubbing inside. Running it can burn out the motor.

  • Set the thermostat to Off.
  • Note where it comes from: the outdoor unit, or the furnace or air handler indoors.
  • Book a technician.

Call an HVAC technician.

A rattle: look for something loose

Why: Rattling is often a stick in the outdoor unit, a loose panel or a loose screw on a cover.

  1. Look in through the top grille with a flashlight: sticks or leaves on the fan. Lift out what you can reach without putting your hand past the grille.
  2. Tighten loose screws on the outside panels.
  3. Power back on. Still rattling, or something hits the fan: a technician.

A musty smell: the filter, the drain and the coil

Why: A musty or mildew smell usually comes from a wet filter, standing water in the drain pan, or growth on the indoor coil.

  1. Change the filter.
  2. Clear the condensate drain (Start over: Water leaking indoors).
  3. Ask for the indoor coil and the pan to be cleaned at the next tune-up.
  4. Mold you can see across more than about 10 sq ft: a professional (EPA).

What's it doing?

Is the outdoor unit running?

Go outside and look and listen. Don't open the unit or reach into it.

Try this first

  1. Check the thermostat is on Cool, not Heat, Auto or Emergency heat, and below the room temperature.
  2. Fan on Auto: on ON it blows between cooling runs, and that air isn't cold (Carrier).

What's it doing?

Did the plug's Reset button bring it back?

Most window units have a plug with Test and Reset buttons (an LCDI): it cuts the power when the cord is damaged.

Try this first

  1. Press Reset on the plug.
  2. Test the outlet with a lamp, and check its breaker and any GFCI.
  3. Plug it straight into the wall: never an extension cord or a power strip (the manuals).

Fixed: keep the filter clean

Why: A room AC's filter sits behind the front grille. Clogged, it cuts the cooling and can make the coil ice (DOE).

  1. Wash the filter every two weeks or so in summer, more with pets.
  2. Plug it straight into the wall: never an extension cord or a power strip.
  3. At the end of summer, clean the fins and clear the drain channels before storing or covering it.

Stop: The plug keeps tripping: stop using it

The Test and Reset buttons on a window unit's plug (an LCDI or ALCI) cut the power when they sense damage in the cord. A plug that trips again means the cord, or the unit, is damaged.

  • Unplug it, and don't tape or bypass the plug.
  • Look for a cut, crushed or scorched cord.
  • Under warranty, contact the maker; otherwise replace the unit.

Replace the unit, or contact the maker.

Time for a new one

Why: A room AC lasts about 10 years (PNNL). Once the sealed part fails (the compressor or a leak), it can't be recharged at home and a repair costs more than a new unit.

  1. Under warranty: contact the maker.
  2. Otherwise, size the new one from the room's square feet, its sun and the people in it (ENERGY STAR's chart).
  3. Look for the ENERGY STAR label: it uses less power for the same cooling.

Did that bring the cold back?

Try this first

  1. Set the mode to Cool, not Fan, Dry or Eco, and the temperature below the room.
  2. Slide out the filter behind the front grille, wash it in warm water, dry it and put it back (DOE).
  3. Outside: clear anything against the back of the unit.

Clean the coil fins and the drain

Why: Dusty or bent fins on the coils can't move heat, and a clogged drain channel makes it drip indoors (DOE).

  1. Take the front grille off and wash the filter.
  2. Vacuum the front coil's fins gently with a brush attachment, along the fins.
  3. Straighten bent fins with a fin comb, front and back.
  4. Clear the drain channels along the bottom with a stiff wire (DOE).
  5. Let it dry, put it back together, plug it in and try Cool.
  6. Still warm: it's probably the sealed part, and time for a new one.

Parts: ac fin comb.

Ice on a room AC

Why: A room AC ices up when its filter is clogged, its fins are dirty, it's set very cold, or it's cool outside.

  1. Switch it to Fan only until the ice melts.
  2. Wash the filter and clean the fins (unplugged).
  3. Check the manual for the lowest outdoor temperature it should cool at; don't run it on Cool on cool nights.
  4. Ice again with a clean filter: the sealed part is failing, and it's time for a new one.

It drips into the room

Why: A window unit should tilt slightly toward the outside so its water runs out the back. Level or tilted in, it drips indoors.

  1. Unplug it.
  2. Put a level on top: the back (outside) should sit a little lower. The manual gives how much; most say about a quarter of a bubble.
  3. Adjust the bracket or the shims under the outside edge.
  4. Clear the drain holes and channels along the bottom with a stiff wire (DOE).

A portable AC's tank or hose

Why: Portable units collect water and switch off when their tank is full; in humid weather that can be every few hours. A long or kinked exhaust hose blows the heat back in.

  1. Empty the tank by the drain plug, or connect a hose to its continuous drain (the manual shows where).
  2. Keep the exhaust hose as short and straight as it goes, and seal the window kit's gaps.
  3. Wash the filter every two weeks in summer.

It may be too small for the room

Why: A room AC sized for less space than it cools runs all day and never catches up. Sun, a kitchen and extra people all add to what the room needs (ENERGY STAR).

  1. Close the blinds on the sunny side, and seal gaps around the unit with the foam that came with it.
  2. Keep the filter clean.
  3. Check its BTU against the room's square feet on ENERGY STAR's chart: a bigger unit may be the answer.

What's it doing?

Did that bring it on?

Try this first

  1. New batteries in the remote; point it at the indoor unit.
  2. The outdoor unit's double breaker, and the disconnect box by it: push the breaker fully OFF, then ON. Once.
  3. Many indoor units have an Auto or Emergency button under the front cover: press it to run without the remote (the manuals).

Fixed: keep the filters clean

Why: A mini-split's indoor filters clog fast: Bryant says clean them every 2–4 weeks, Carrier every 4–6.

  1. Rinse the filters monthly while it's cooling or heating, and let them dry fully before they go back.
  2. Keep 2 ft clear around the outdoor unit.
  3. Have it serviced once a year (Carrier): the indoor coil and blower wheel need a technician's cleaning.

Stop: The outdoor unit won't run: a technician's job

With the breaker on and the disconnect in, an outdoor unit that stays off is a control board, sensor or wiring problem. A mini-split's boards are live at 240 V.

  • Turn it off with the remote.
  • Note any blinking light or code on the indoor unit.
  • Book a technician who services your brand.

Call an HVAC technician.

Did that bring the cold back?

Try this first

  1. Set the mode to Cool (the snowflake), not Dry, Fan or Auto, and the temperature below the room.
  2. Lift the front cover, slide out the mesh filters, rinse them in lukewarm water, let them dry fully and slide them back (Carrier).
  3. Outside: clear plants and things back 2 ft from the outdoor unit.

Look the code up

Why: A blinking light or a code on the indoor unit is the unit telling you what's wrong. Codes differ by brand and model.

  1. Count the blinks, or write down the code.
  2. Look it up in the owner's manual or on the maker's site for your model.
  3. A filter or cleaning reminder: clean the filters, then reset it as the manual says.
  4. Switching it off at the breaker for a minute clears some codes. One that comes back needs a technician.

A dripping indoor unit

Why: A mini-split's indoor unit drains through a small hose. Dirty filters make the coil ice and overflow; a kinked or clogged hose backs up.

  1. Turn it off with the remote and clean the filters.
  2. Outside, find the drain hose's end: straighten kinks, and pull a clog out with a wet/dry vac held tight over the end.
  3. Still dripping: a technician cleans the drain pan and the coil (a mini-split cleaning).

What the outdoor unit tells you

With the thermostat on Cool and set below the room temperature, go outside and look and listen. Don't open it.

You see or hearUsuallyWhat to do
Fan spins, steady humIt's runningCheck the filter, then the fins. Still warm: a technician (refrigerant)
SilentNo power, or no signal from the thermostatThe double breaker, the disconnect box, then wait 5 minutes
Hums or buzzes, fan stillA capacitor or motor won't start itStop: thermostat off, a technician
Clicks, then nothingThe contactor or capacitorStop: a technician
Ice on the copper pipesToo little air, or low refrigerantCool off, fan on to thaw; change the filter. Comes back: a technician
Grinding or screechingA motor bearingStop: thermostat off, a technician

Where the answers come from

  1. The checks: Carrier's troubleshooting, coil, frozen-AC and drain-line guides; Trane on the overflow switch; Goodman's manual on the blower door switch; ENERGY STAR's maintenance checklist (check the filter monthly in summer).
  2. Window units and mini-splits: DOE Energy Saver on room AC upkeep (filter, fin comb, drain channels); Bryant and Carrier on rinsing mini-split filters.
  3. The stops: EPA Section 608 (only certified technicians buy refrigerant) and the R-22 phase-out; Daikin's service manual (capacitors hold a charge); Carrier (don't troubleshoot capacitors, motors or the compressor; a breaker that trips again or ice that comes back means a technician).
  4. Sizing and short cycling: DOE and NREL on oversized systems; ACCA on the 14–20 °F rule (a clue, not a test). Costs: Fixr and PickHVAC (2026).

You may

Set
the thermostat, and change its batteries
Reset
a breaker once, and the disconnect
Change
the filter; rinse the outdoor coil with the power off
Clear
the condensate drain, and swap a plug-in condensate pump
Never
open the outdoor unit, touch a capacitor, or add refrigerant

Not yet reviewed by a licensed HVAC technician. Your unit's manual wins.

Questions people ask

Why is my AC running but not blowing cold air?

Check the easy things first: the thermostat on Cool with the fan on Auto (on ON, the fan blows between cooling runs), a clogged filter, and the outdoor unit. If the outdoor unit is silent, check its breaker and the disconnect box beside it. If it runs, look at its fins: matted with dirt or fluff, it can't shed heat. A clean filter, a clean coil and a running outdoor unit with warm air usually means a refrigerant leak, which only an EPA-certified technician can fix.

Why is there ice on my AC?

Too little air across the indoor coil (a clogged filter, closed vents or blocked returns) or low refrigerant. Turn cooling off and the fan on to thaw it: frost takes about 1 to 3 hours, thick ice 4 to 8 hours or more. Never chip it or use heat. Change a dirty filter and open the vents. If the ice comes back, call a technician (Carrier).

Why is my AC leaking water inside?

The condensate drain is clogged, the pan is full, or a condensate pump has stopped. With the AC off, pull the clog out of the drain's outside end with a wet/dry vac, then pour a cup of distilled white vinegar into the cleanout (Carrier). A float switch shuts the AC off when the pan fills, so clearing the drain often brings the cooling back too.

Can I add refrigerant to my AC myself?

No. Since 2018 only EPA Section 608 certified technicians may buy refrigerant for home AC systems, and refrigerant isn't used up: if it's low, there's a leak to find and fix. Systems made before 2010 usually use R-22, which hasn't been made since 2020, so topping it up is expensive.

Why does my outdoor AC unit hum but the fan doesn't spin?

Usually a failed capacitor, the part that helps the fan motor and the compressor start. Turn the AC off at the thermostat so the compressor stops trying to start, switch off the disconnect, and call a technician. A capacitor holds a charge that can shock you even with the power off, so don't open the unit or push the fan with a stick.

More apps