Ceiling fan wiring
At the ceiling, join white to white, all the grounds together (box, bracket, downrod) and the house black to the fan's black (the motor). The fan's blue lead runs the light: with one wall switch join it to the black too; with two switches (a red wire in the box) join it to the red. The box must be marked as acceptable for fan support, up to 70 lb, and a wall dimmer has to come out (Hunter; NEC 314.27(C)).
One wall switch
Ceiling box
Two wall switches (fan and light)
Wall switch box
Ceiling box
The box
A light fixture box isn't a fan box. Look inside for "Acceptable for fan support" and a weight; the fan hangs from that box's own screws (Hunter). Not there, or not sure: a fan-rated box and brace goes in from below, between the joists, before the fan does.
Step by step
First
- Turn off the breaker. A wall switch off is not enough. Put tape or a note on the breaker so nobody turns it back on.
- Prove it's dead: check your tester on an outlet you know is live, test every wire in the box, then check the tester on the live outlet again (Klein). A voltage pen alone isn't proof: use a plug-in or two-probe tester where you can.
- Take a photo of the wires before you move any of them.
Then
- Check the ceiling box first: it must be marked as acceptable for fan support and fixed to the framing (Hunter: 70 lb). If not, put in a fan-rated box or brace.
- A dimmer on the wall comes out: a plain switch or a fan-rated control goes in (Hunter).
- Hang the fan from its bracket, then join: all grounds together (box, bracket, downrod), white to white, the ceiling black to the fan's black (and blue, with one switch), the red to the blue with two switches (Hunter).
- Cap any wire you don't use with a wire nut, tuck the hot wires to one side of the box and the rest to the other.
- Breaker on: test the fan, the light and the reverse switch.
No ground at the ceiling: stop, a fan needs one (Hunter).
Stop and call an electrician
- Wires that test live with the breaker off: stop and call an electrician (Leviton).
- Aluminum wire (dull silver, or "AL" on the cable): a fire risk at outlets and switches, don't touch it yourself (CPSC).
- Cloth-covered wires on porcelain knobs or tubes (knob-and-tube).
- Scorched, melted or brittle insulation, or a plate that's warm to the touch (CPSC).
- A 3-wire cable whose black and red come from two breakers sharing one white (a shared neutral).
- Wires that don't match any of these diagrams, or you can't tell which is which.
- No ground wire at the ceiling (Hunter), or a box that isn't fan-rated and has no framing behind it to fix one to.
From Hunter Fan installation guides and support, and EC&M and the NC fire marshal on fan boxes, the CPSC, and the NEC as explained by EC&M, IAEI and JLC. Code years differ by city. · Not yet reviewed by a licensed electrician