4-way switch wiring

A 4-way switch goes between two 3-way switches when three or more switches run one light. It has four traveler screws and no common, in two pairs: a brass pair and a black pair, or a pair marked IN and one marked OUT. The black and red travelers from one 3-way go on one pair, the black and red from the other 3-way on the other pair (Leviton). Splitting one cable's pair across both sides is the mistake: then the light works only in some switch positions.

The 4-way wiring diagram

Power at the first 3-way, a 4-way in the middle, the light after the last 3-way.

Breakerpanel2-wireFirst 3-way3-wire4-way box3-wireLast 3-way2-wireLight box

4-way box

3-wire3-wire4-way switchPair 1 (brass)Pair 1 (brass)Pair 2 (black)Pair 2 (black)Ground (green screw)From the first 3-wayTo the last 3-way
Flip any of the three switches and the light changes: our test checks all eight positions.

Step by step

First

  1. Turn off the breaker. A wall switch off is not enough. Put tape or a note on the breaker so nobody turns it back on.
  2. Prove it's dead: check your tester on an outlet you know is live, test every wire in the box, then check the tester on the live outlet again (Klein). A voltage pen alone isn't proof: use a plug-in or two-probe tester where you can.
  3. Take a photo of the wires before you move any of them.

Then

  1. Before taking it off, put a tape flag on the two wires from one cable and a different flag on the two from the other.
  2. Land one cable's pair on one pair of screws (the brass pair, or the ones marked IN) and the other cable's pair on the other (black, or OUT) (Leviton).
  3. Never split a cable's pair across both sides.
  4. Ground on the green screw, then test from every switch.

Stop and call an electrician

Open the 4-way drawing

From Leviton 5604 and A5624 instruction sheets, UHMC and This Old House, the CPSC, and the NEC as explained by EC&M, IAEI and JLC. Code years differ by city. · Not yet reviewed by a licensed electrician