Delta shower cartridge: which one you have, and how to replace it
A Delta shower with one handle that only sets the temperature takes the RP46074 if the valve was made after March 2006 (MultiChoice 13 or 14 Series), or the RP19804 in an older Monitor 1300 or 1400 valve. A shower with a separate volume handle is a 17 Series: RP46463, or RP32104 before March 2006. Not sure of the date? Pull the old cartridge: the RP46074 has a grey cap and a longer lower housing, the RP19804 a white cap and a shorter, blue one. A defective cartridge is replaced free under Delta's lifetime warranty for the original owner.
Which Delta cartridge you have
Count the controls on the wall first. One lever or knob that only changes the temperature is a 13 or 14 Series (or the older 1300 or 1400): the 13 and 14 take the same cartridge. A volume handle plus a temperature knob or dial is a 17 or 17T Series. To tell a 13/14 from an older 1300/1400, go by when the valve went in, or look at the cartridge once the sleeve and bonnet nut are off.
- RP46074MultiChoice 13 and 14 Series, made after March 2006 · one handle, temperature onlyGrey cap, longer off-white lower housing
- RP74236MultiChoice 13 and 14 Series, ceramic (models ending -CER) · one handle, temperature onlyWhite cap, grey body
- RP19804Monitor 1300 and 1400 Series, made before March 2006 · one handle, temperature onlyWhite cap, shorter blue (older: off-white) lower housing
- RP46463MultiChoice 17 Series, made March 2006 and after · separate volume and temperatureGrey cap, V notch, adapter (RP46073), shorter tab
- RP32104Monitor 1700 and 1800 Series, made before March 2006 · separate volume and temperatureWhite cap, square notch, longer tab
- RP47201MultiChoice 17T Series (TempAssure thermostatic) · separate volume and temperature5⅝ in tall
The RP19804 and RP46074 aren't interchangeable: they fit different valve bodies. An old 600 Series valve has a ball, not a cartridge (Delta sells renovation kit RP54870), and a 1600 Series (1974 to 1993) takes the RP1991 stem unit. Still not sure: Delta's product identifier at deltafaucet.com, or 1-800-345-DELTA.
Spout dripping? Try seats and springs first
On a 13 or 14 Series, Delta's first fix for a drip from the spout or showerhead is the RP4993 seats and springs, with the RP14414 O-rings, a few dollars. Replace the whole cartridge only if it keeps dripping. To check an RP46074 in hard water, turn it to the middle (full mix) position and shake it hard: a rattle means it still works; no rattle, replace the housing.
Replace an RP46074 (13 and 14 Series)
Delta lists a Phillips screwdriver, an Allen wrench, an adjustable wrench and Teflon tape. No special puller.
- Shut off the water to the shower.
- Take the handle off (a set screw under a cap or on the side), then the sleeve.
- Note where the white rotational limit stop sits on the cartridge cap: the anti-scald setting. The new one goes back in the same position.
- Unscrew the bonnet nut. It should come off by hand; if it's stuck, wrap it in a towel and use channel locks while you hold the valve still.
- Don't pry the cartridge out with a screwdriver. Put the handle back on the stem, turn it counterclockwise about a quarter turn past the stop, and lift the cartridge out.
- Put the new one in with the words "hot side" on the left (on the right only for back-to-back or reversed plumbing). The tubes and O-rings at the bottom must seat in the holes in the valve, and the keys in their slots.
- Thread the bonnet nut on hand-tight. Put the sleeve and handle back.
- Turn the water on. Cold water must come out first when you open the handle.
Set the limit stop: hot enough, never scalding
- Run the shower until the water is as hot and as cold as it gets.
- Turn the handle counterclockwise until it stops (the hottest it allows) and hold a thermometer in a plastic cup in the stream.
- Above 120°F: take the handle off and move the limit stop clockwise (cooler). On cartridges from August 2014 on, pull the white stop out, turn it and push it fully back in; on older ones, pull the disc back, move the stop and push the disc fully home. Each tooth is about 4°F to 16°F.
- Water only lukewarm: one tooth counterclockwise at a time, as long as it stays at 120°F or less. Delta says it may need resetting with the seasons.
On the older RP19804 the stop works the other way: mark it before you pull it off, pull the black retention plug off the new cartridge's stem and throw it away, and move the stop one tooth counterclockwise for about every 6°F cooler. Then flush the lines for a minute before you use it. Follow the sheet in your cartridge's box.
When it doesn't go right
- Hot and cold are reversed: the cartridge is in 180° off. Take it out and turn it so "hot side" faces the hot supply (left, normally). Delta says the same flip fixes back-to-back valves and supplies piped to the wrong sides.
- The cartridge won't come out: the handle trick above, not a screwdriver. Third-party cartridge pullers exist for the 1300/1400 and 13/14 valves; Delta doesn't make one.
- Only lukewarm water: the limit stop, not the cartridge. One tooth hotter at a time.
- Water still drips: on a 13/14, replace the seats and springs too (RP4993).
Getting one free under the warranty
Delta replaces a part that proves defective, free, for as long as the original buyer owns the home it was installed in (labor isn't covered). You need the receipt, or the faucet registered with Delta, and it must have come from an authorized seller. Ask by phone at 1-800-345-DELTA (3358), the chat in Delta's Help Center, or the contact page at deltafaucet.com/service-parts/contact-us, with the model number and purchase date. There's no warranty form online.
From Delta's 13/14 Series owner's manual (68881 Rev. M) and its cartridge reference sheet, the RP19804 sheet (34459), the 17 Series manual (107529 Rev. H), the RP32104 sheet (64655), and Delta's parts, FAQ and warranty pages, checked November 2026. Spetz isn't affiliated with Delta Faucet Company. · Not yet reviewed by a licensed plumber