How deep should a French drain be?
A French drain in the yard is 18 to 24 in deep and 12 to 18 in wide (LSU AgCenter), with 2 to 3 in of stone under the 4 in pipe. It has to fall at least 1% to the outlet, about 1 ¼ in every 10 ft (NDS), so on flat ground it gets deeper toward the low end. A drain 8 to 24 in deep is a DIY job; deeper, or along the foundation, is a contractor's (Delaware DNREC). A curtain drain that catches water running down a slope is usually 2 ft deep or more, across the slope.
Depth on flat ground, by length
Starting 18 in deep, with 10 ft of solid pipe on to the outlet, the bottom falling 1% the whole way.
| Drain | Fall needed | Depth, top → outlet |
|---|---|---|
| 25 ft | 4 ¼ in | 18 → 22 ¼ in |
| 50 ft | 7 ¼ in | 18 → 25 ¼ in |
| 75 ft | 10 ¼ in | 18 → 28 ¼ in |
| 100 ft | 13 ¼ in | 18 → 31 ¼ in |
| 150 ft | 19 ¼ in | 18 → 37 ¼ in |
Where the ground itself falls, the trench can stay the same depth. Over 4 ft deep is a pro's job: OSHA requires cave-in protection for workers from 5 ft.
From the bottom up
- Non-woven filter fabric lining the trench, with enough left to fold over the top (Mirafi).
- 2 to 3 in of clean ¾–1 ½ in stone (IRC R405.1: 2 in at least).
- 4 in perforated pipe, holes down (Mirafi, U.S. DOE).
- Stone around and over it, the fabric folded over, then 8 in of soil and sod, or stone to the top to catch water running over the ground.
From LSU AgCenter, NDS, Delaware DNREC, the IRC (R405.1) and OSHA's trench rules; depths from the planner's math.