M6 tap drill size
An M6 x 1.0 tap takes a 5 mm drill bit (.1969 in), which cuts about 77% of a full thread: the usual choice in steel and aluminum. An inch-size bit that works: #8.
Every bit that works for M6
Thread % is how deep the tap cuts compared with a full thread. Around 75% holds as well as the bolt in most metal; going past it adds little strength and makes the tap much harder to turn and easier to break. In hard steel, or a deep hole, go one bit bigger (less thread). In soft plastic or wood, more thread holds better.
| Bit | Thread | Decimal in | mm |
|---|---|---|---|
| #5 | 60% | .2055 | 5.22 |
| 5.2 mm | 62% | .2047 | 5.20 |
| #6 | 63% | .2040 | 5.18 |
| #7 | 69% | .2010 | 5.11 |
| 5.1 mm | 69% | .2008 | 5.10 |
| #8 | 73% | .1990 | 5.05 |
| 5 mm (the chart's pick) | 77% | .1969 | 5.00 |
| #9 | 79% | .1960 | 4.98 |
| #10 | 84% | .1935 | 4.91 |
| 4.9 mm | 85% | .1929 | 4.90 |
How to tap an M6 hole
- Center-punch the spot so the bit doesn't wander.
- Drill with the 5 mm bit, square to the surface. A drill press keeps it straight; by hand, sight it from two sides.
- Countersink the edge lightly, so the first thread doesn't raise a burr.
- Start the tap square, with a drop of cutting oil in metal. With a hand tap, turn it about a half turn in and a quarter turn back to break the chip. A spiral-point (gun) tap in a through hole can go straight in.
- In a blind hole, drill deeper than the thread you need and back the tap out to clear the chips before it bottoms out.
Same size, other threads: 1/4-20 (#7).
Tap drills from Little Machine Shop's 75% thread column, Fastenal second; number and letter sizes per ASME B94.11M; thread % = 76.98 × (major diameter − drill) ÷ pitch, the standard formula for 60° threads (Machinery's Handbook).